Search Engine Site Map Contact Us
About Xypex Xypex Products Secifications Applications Projects
Spec-Data
CSI Format
Schematic Drawings
  Schematic Drawings

 
Drawings:
  Sewage Plant Clarifier Tank
 

Sewage Plant Clarifier Tank

1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd. (1.0 kg/m2).
2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2), then fill slot to surface with Xypex Concentrate in Dry-Pac form.
2 To all ceiling, wall, and floor surfaces, apply one slurry coat of Xypex Concentrate at the rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg/m2). After the Concentrate has set, but while it is still "green", apply a coat of Xypex Modified at the rate of 1.25 to 1.5 lb./sq. yd. (0.65 to 0.8 kg/m2).

Note: For horizontal surfaces in new construction, Xypex Concentrate DS-1 can be used in lieu of standard Xypex coating system.

Schematic diagram shows Xypex application only and does not depict the standard requirements for waterstops or expansion joint sealant.

The specifier can consider the alternative use of Xypex Dry Shake or Xypex Admix, where applicable.

Refer to Standard Specifications for further information.

 

 


 
About Xypex  |  Xypex Products  |  Specifications  |  Application  |  Projects


Home  |  Search Engine  |  Site Map  |  Contact Us

 

© 1999, Xypex Chemical Corporation. All rights reserved.